🚧 Change module numbering

This commit is contained in:
Jonas Bengtsson
2026-10-04 13:05:47 +02:00
parent 7948b794f5
commit e5df0b04ed
17 changed files with 644 additions and 138 deletions
+18
View File
@@ -0,0 +1,18 @@
# Virtual WAGO node configuration — saved from the web UI (SAVE CONFIG)
# Simulated device: WAGO 750-362 Modbus TCP coupler
# Edit by hand or via the UI; comments are not preserved on UI saves.
name: pump_node
coupler: 750-362
modules:
- "750-1405" # 16-channel DI 24VDC
- "750-430" # 8-channel DI 24VDC
- "750-530" # 8-channel DO 24VDC
- "750-1516" # 16-channel DO 24VDC
- "750-467" # 2-channel AI 4-20mA
- "750-554" # 2-channel AO 4-20mA
# Application names for module channels (I/O code -> name)
channel_names:
AO0.0: speed_setpoint
DI0.0: start_button