🚧 Rewrite continous simulation.
This commit is contained in:
@@ -0,0 +1,8 @@
|
||||
"""User-authored plant environments (spec FR-8.2.17).
|
||||
|
||||
Each module here is loadable by reference:
|
||||
|
||||
wago-sim serve --node ... --env envs.pump_station_env:PumpStationEnv
|
||||
wago-sim sim --node ... --env envs.pump_station_env:make_env
|
||||
wago-sim serve --node ... --env envs.pump_station_env # picks Env
|
||||
"""
|
||||
@@ -0,0 +1,74 @@
|
||||
"""Example pump-station plant environment (spec FR-8.2.17).
|
||||
|
||||
Demonstrates environment authoring: subclass PlantEnv, override
|
||||
``model()`` — read what the PLC commanded (DO/AO), compute what the
|
||||
field now shows (DI/AI). Run it live against a Modbus master:
|
||||
|
||||
wago-sim serve --node config/pump_node.yaml --port 5020 \
|
||||
--env envs.pump_station_env:PumpStationEnv
|
||||
|
||||
or headless for model development:
|
||||
|
||||
wago-sim sim --node config/pump_node.yaml \
|
||||
--env envs.pump_station_env:PumpStationEnv
|
||||
|
||||
Physics (deliberately simple, for demonstration): one tank.
|
||||
- inflow is constant (or a small sinusoidal demand profile)
|
||||
- the pump drains at `flow_max * capacity * speed` while DO0.0 is ON
|
||||
- the level integrates the balance; AI0.0 reports it as 0.1 mm/count
|
||||
- a low-level switch DI0.1 opens when the tank drains below 500 mm
|
||||
- optional is_done: stop after a sim hour (default: run forever)
|
||||
"""
|
||||
|
||||
from __future__ import annotations
|
||||
|
||||
from wago_sim.scenario.plantenv import PlantEnv, PlantState
|
||||
|
||||
TANK_AREA = 2.0 # m^2
|
||||
FLOW_MAX = 30.0 # m^3/h the pump moves at full speed
|
||||
INFLOW = 12.0 # m^3/h constant inflow
|
||||
LEVEL_MAX = 9000.0 # mm — tank brim
|
||||
SWITCH_AT = 500.0 # mm — low-level switch threshold
|
||||
|
||||
|
||||
class PumpStationEnv(PlantEnv):
|
||||
"""Closed-loop tank + pump physics over the pump_node layout."""
|
||||
|
||||
def __init__(self, *args, stop_after_ms: float | None = None, **kw):
|
||||
super().__init__(*args, **kw)
|
||||
self._level_mm = 3000.0 # initial tank level
|
||||
self.stop_after_ms = stop_after_ms
|
||||
|
||||
def model(self, state: PlantState, dt_s: float) -> dict[str, object]:
|
||||
dt_h = dt_s / 3600.0
|
||||
# what the PLC currently commands
|
||||
pump_on = bool(state.by_code("DO0.0"))
|
||||
# optional speed setpoint from AO0.0 (counts -> 0..1 fraction)
|
||||
speed_raw = float(state.by_code("AO0.0") or 0)
|
||||
speed = min(1.0, max(0.0, speed_raw / 4095.0))
|
||||
# physics: water balance with pump wear (parameters attachable)
|
||||
capacity = state.parameters.get("pump_capacity", 1.0)
|
||||
outflow = FLOW_MAX * capacity * speed if pump_on else 0.0
|
||||
d_level_mm = (INFLOW - outflow) / TANK_AREA * 1000.0 * dt_h
|
||||
self._level_mm = min(LEVEL_MAX, max(0.0, self._level_mm + d_level_mm))
|
||||
# the field the PLC reads back
|
||||
level_counts = int(self._level_mm / 0.1) # AI0.0: 0.1 mm/count
|
||||
low_switch = self._level_mm < SWITCH_AT # DI0.1
|
||||
return {
|
||||
"AI0.0": level_counts,
|
||||
"DI0.1": low_switch,
|
||||
}
|
||||
|
||||
def is_done(self, state: PlantState) -> bool:
|
||||
if self.stop_after_ms is None:
|
||||
return False # default: run until stopped
|
||||
return state.sim_time_ms >= self.stop_after_ms
|
||||
|
||||
|
||||
def make_env(node=None, engine=None) -> PumpStationEnv:
|
||||
"""Factory form (FR-8.2.17): envs.pump_station_env:make_env."""
|
||||
return PumpStationEnv(node=node, engine=engine)
|
||||
|
||||
|
||||
# bare-module form: `--env envs.pump_station_env` picks this up
|
||||
Env = PumpStationEnv
|
||||