🚧 WIP
This commit is contained in:
@@ -5,9 +5,9 @@
|
||||
| | |
|
||||
|---|---|
|
||||
| Project | `wago-modbustcp-simulator-py` |
|
||||
| Version | 1.2 (Draft for review) |
|
||||
| Version | 1.3 (Draft for review) |
|
||||
| Date | 2026-10-03 |
|
||||
| Status | Framework phase; module addressing implemented (FR-4.3.11); long-duration simulation (§8), bench mode (§9), web UI (§10) and runtime device configuration (§11) requested |
|
||||
| Status | Framework phase; module addressing implemented (FR-4.3.11); service/container deployment implemented (§12); plain-text request tracing implemented (NFR-6.4); clean CLI error handling implemented (NFR-6.5 CLI part); long-duration simulation (§8), bench mode (§9), web UI (§10) and runtime device configuration (§11) requested |
|
||||
| Target device simulated | WAGO 750-362 / 750-362/0000-0001 FC Modbus TCP (G4) bus coupler |
|
||||
| Reference documents | `docs/m07500362_xxxxxxxx_0en.pdf` (750-362 Modbus TCP manual), Modbus TCP specification (modbus.org) |
|
||||
|
||||
@@ -434,8 +434,23 @@ stateDiagram-v2
|
||||
- NFR-6.1 Performance: sustain ≥ 500 requests/s with ≤ 10 ms added latency (typical FAT bench load).
|
||||
- NFR-6.2 Portability: Python 3.11+ on Windows/Linux.
|
||||
- NFR-6.3 Determinism: two runs of a scenario with identical inputs and timing produce identical verdict logs (except wall-clock stamps).
|
||||
- NFR-6.4 Observability: every Modbus transaction logged with timestamps (sim-time + wall-time), PDU hex, connection id.
|
||||
- NFR-6.5 Robustness: malformed frames never crash the server; counted in statistics.
|
||||
- NFR-6.4 Observability: every Modbus transaction is observable in
|
||||
verbose mode (`-v` / `WAGO_SIM_VERBOSE`) as plain text — decoded
|
||||
`REQ`/`RSP`/`EXC` lines with transaction id, unit, function name,
|
||||
values, and the WAGO 750-362 register-map meaning of each address
|
||||
(process areas with %IW/%QW mapping per Tables 119/120, read-back
|
||||
mirrors, configuration/constant registers, illegal areas); malformed
|
||||
frames are traced as `RAW` lines with PDU hex. *Implemented*
|
||||
(`src/wago_sim/trace.py`).
|
||||
- NFR-6.5 Robustness: malformed frames never crash the server; counted in
|
||||
statistics. Invalid operator input — unknown commands or options,
|
||||
non-numeric or out-of-range port numbers (CLI or
|
||||
`WAGO_SIM_PORT`), missing/unparsable node or scenario files,
|
||||
unwritable report paths — yields a one-line
|
||||
`wago-sim: error: …` on stderr and exit code 2, never a Python
|
||||
traceback; missing report directories are auto-created; unexpected
|
||||
internal errors keep the traceback (logged) for debugging.
|
||||
*CLI part implemented* (tested in `tests/test_cli.py`).
|
||||
- NFR-6.6 Configurability: port, bind address, node config, firmware identity registers, MAC-ID configurable without code changes.
|
||||
|
||||
---
|
||||
@@ -1065,7 +1080,56 @@ This feature request closes that gap.
|
||||
|
||||
---
|
||||
|
||||
## 12. Roadmap (post-framework)
|
||||
## 12. Deployment — Service / Containerized Operation
|
||||
|
||||
> **Status: implemented 2026-10-03 (v1.3).** The simulator can run as a
|
||||
> long-lived service: docker/compose container, or a systemd unit on bare
|
||||
> metal/VM. Verified: image builds, container answers Modbus requests,
|
||||
> and `docker stop` (SIGTERM) shuts down gracefully in < 1 s.
|
||||
|
||||
### 12.1 Motivation
|
||||
|
||||
A FAT bench simulator is infrastructure: it must start on boot, survive
|
||||
restarts, log to the platform's log pipeline, and stop cleanly so a
|
||||
connected PLC sees a controlled fieldbus-node failure rather than a
|
||||
> hung socket — the exact condition watchdog/FAT fault cases test.
|
||||
|
||||
### 12.2 Requirements (all implemented)
|
||||
|
||||
- FR-12.2.1: **Environment-variable configuration**: `WAGO_SIM_NODE`,
|
||||
`WAGO_SIM_HOST`, `WAGO_SIM_PORT` configure `serve` without CLI arguments
|
||||
(container `CMD ["wago-sim", "serve"]` needs zero arguments).
|
||||
Explicit CLI arguments override environment values.
|
||||
- FR-12.2.2: **Graceful shutdown**: on SIGINT/SIGTERM (docker stop,
|
||||
systemctl stop) the server closes all client connections and the
|
||||
listening socket via `server.stop()` before exiting — no forced kill,
|
||||
no lingering sockets. Verified: `docker stop` completes in 0.34 s.
|
||||
- FR-12.2.3: **Container image** (`Dockerfile`): `python:3.12-slim`,
|
||||
non-root `wago-sim` user, unbuffered stdout logging, baked-in example
|
||||
config for out-of-the-box startup, TCP health check, ~197 MB image.
|
||||
- FR-12.2.4: **Compose service** (`docker-compose.yml`): port mapping
|
||||
(5020→502 default; 502 needs privileges on some hosts), read-only
|
||||
mounts for config/scenarios/plugins, writable `out/` for reports,
|
||||
resource limits, log rotation, `restart: unless-stopped`.
|
||||
- FR-12.2.5: **systemd unit** (`deploy/wago-sim.service`): dedicated
|
||||
service user, env-var configuration, `Restart=on-failure`, hardened
|
||||
(NoNewPrivileges, ProtectSystem, CAP_NET_BIND_SERVICE for port 502
|
||||
without root).
|
||||
- FR-12.2.6: Logs to stdout/stderr only (docker json-file / journald
|
||||
collect them); single-line format, no ANSI colors.
|
||||
|
||||
### 12.3 Acceptance criteria (all verified)
|
||||
|
||||
1. `docker build -t wago-sim .` succeeds; image ~197 MB.
|
||||
2. `docker run -p <host>:502 -e WAGO_SIM_NODE=... wago-sim` serves
|
||||
Modbus (constants `0x2000–0x2008` read correctly from the container).
|
||||
3. `docker stop` completes in < 1 s with clean shutdown logs.
|
||||
4. `docker compose up -d` starts a healthy service; `down` tears it down.
|
||||
5. CLI tests cover env-var configuration and override precedence.
|
||||
|
||||
---
|
||||
|
||||
## 13. Roadmap (post-framework)
|
||||
|
||||
| Phase | Feature |
|
||||
|---|---|
|
||||
@@ -1077,7 +1141,7 @@ This feature request closes that gap.
|
||||
|
||||
---
|
||||
|
||||
## 13. References
|
||||
## 14. References
|
||||
|
||||
- WAGO 750-362 manual `m07500362_xxxxxxxx_0en.pdf`, sections 7.2–7.3 (process image), 11.2 (Modbus), 12.2 (module data architecture)
|
||||
- WAGO I/O System 750 system description `m075xxxxx_xxxxxxxx_0en.pdf`
|
||||
|
||||
Reference in New Issue